U-value calculator
Thermal transmittance of a wall or roof from its layers.
How it is calculated
R of each layer = thickness (m) ÷ conductivity λ (W/m·K). Total R = Rsi + ΣR + Rse. U = 1 ÷ total R (W/m²·K). Surface resistances follow ISO 6946 for the heat-flow direction.
Check locally: A simplified layer calculation: it does not include thermal bridges, fixings or air gaps beyond the layers you add.
How to use the U-value Calculator
Calculate the U-value of a wall, roof or floor from its layers, so you can check thermal performance against an energy code or compare build-ups.
- Choose the element and the direction of heat flow.
- Add each layer from outside to inside with its material, thickness and thermal conductivity (lambda).
- The calculator adds the standard surface resistances for the element.
- Read the U-value in W/m²·K, the total R and the imperial equivalents.
Worked example
A 230 mm common brick wall with 15 mm of cement plaster on one side and 12 mm on the other has layer resistances of 0.021, 0.299 and 0.017 m²·K/W. Adding the surface resistances (Rsi 0.13 and Rse 0.04) gives a total R of 0.506 m²·K/W, so the U-value is 1 ÷ 0.506 = 1.975 W/m²·K. In imperial units that is R-2.9.
Good to know
- A lower U-value means better insulation. Adding an insulation layer raises R and lowers U.
- Use the conductivity values from the product data sheet or a recognised table. Values in the calculator are typical and not guaranteed.
- This method is for uniform layers. Thermal bridges, air gaps and moisture need a more detailed calculation.
Questions
What is the difference between U and R?
R is resistance to heat flow (higher is better); U is 1 ÷ total R, the heat flow per square metre per degree (lower is better).
Is anything I enter saved or sent?
No. The calculation runs in your browser. Nothing you type is sent anywhere. You can copy the result, print it or download it as a CSV.